Field Splice Code Check (AASHTO) [EX1-STG]

Field Splice Code Check (AASHTO) [EX1-STG]

Please follow the instructions provided below to create Field Splice code check (according to AASHTO).

1

In this section, we will assign an "Field Splice" to perform the Code Check.

2

Navigate to Superstructure Code Checks > Field Splice Code Check (AASHTO)

 

3

Click three-dots icon on Splice and select as SPL3

 

You can choose more “Field Splice” from combobox.

4

Click three-dots icon on Code Check Template.

 

Select the FSCCTTG1 "Field Splice Code Check" template defined in the previous steps for all.

5

You can make adjustments to the “Girder Parameters” tab if you wish.

6

Navigate to Stiffener tab.

Enter data as follows:

Transverse stiffener spacing at left girder [in]: 20

Transverse stiffener spacing at right girder [in]: 20

 

 

 


1

Navigate to Field Splice Code Check (AASHTO) under Superstructure Code Checks on the tree view.

2

Copy General, Girder Parameters and Stiffener from model inputs and paste into OpenBrIM.

The Field Splice Code Check (AASHTO) have been created.


Field Splice Code Check (AASHTO)

Field Splice Code Check (AASHTO)

General

Girder Parameters

Stiffener

BFSCCAASHTONETG1 SPL3 FSCCTTG1 50
BFSCCAASHTONETG1 InteriorPanel
BFSCCAASHTONETG1 NO YES YES 20 20 5

 

Related content

Field Splice Code Check Template [EX1-SIG]
Field Splice Code Check Template [EX1-SIG]
More like this
Bolted Field Splice Code Check (AASHTO) [EX1-SIG]
Bolted Field Splice Code Check (AASHTO) [EX1-SIG]
More like this
Lateral Bracing Code Check (AASHTO) [EX1-STG]
Lateral Bracing Code Check (AASHTO) [EX1-STG]
More like this
Bolted Field Splice [EX1-SIG]
Bolted Field Splice [EX1-SIG]
More like this
Shear Stud Code Check (AASHTO) [EX1-SIG]
Shear Stud Code Check (AASHTO) [EX1-SIG]
More like this
Steel I Girder Code Check (AASHTO) [EX1-SIG]
Steel I Girder Code Check (AASHTO) [EX1-SIG]
More like this