Shear Stud Code Check (AASHTO) [EX1-SIG]

Shear Stud Code Check (AASHTO) [EX1-SIG]

After clicking on ‘Superstructure Code Checks> Shear Stud Code Check (AASHTO)' in the navigation treeview, follow the steps to define the Shear Stud Code Check. You can use the collapsed documentation page below for more information on the explanations of each parameter.

1

Go to General tab. Click the three-dots icon on the Girder cell, and then set G1.

 

image-20250121-084701.png
image-20250121-084712.png

 

2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the code check template is define in the next step.

3

4

Click the three-dots icon on the Code Check Template cell, and then set SStudCCT.

 

 

5

Enter the Check Every Nth Station as 30.

 

 

6

Click three-dots icon on Res. Case to Find Pos. Neg. Flexure Zone cell and select a Result Extraction Case as DC1.

7

Set name as SStudCC.

 

 

8

Keep the parameters in the Reinforcement tab as default.

 

 

9

Proceed to the next step to verify the model.

The completed shear stud code check is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

 

Related content

Shear Stud Code Check Template [EX1-SIG]
Shear Stud Code Check Template [EX1-SIG]
More like this
Steel I Girder Code Check (AASHTO) [EX1-SIG]
Steel I Girder Code Check (AASHTO) [EX1-SIG]
More like this
Cross Frame Code Check (AASHTO) [EX1-SIG]
Cross Frame Code Check (AASHTO) [EX1-SIG]
More like this
Pier Cap Code Check [EX1-SIG]
Pier Cap Code Check [EX1-SIG]
More like this
Pile Capacity Check Template [EX1-SIG]
Pile Capacity Check Template [EX1-SIG]
Read with this
Shear Stud Code Check (AASHTO) [SIG]
Shear Stud Code Check (AASHTO) [SIG]
More like this