Design Summary [EX1-SIG]
Follow the next steps to analyze and design.
1 | Click Analyze icon.
If you have made changes to the model after the analysis and want to use the old analysis results, you can refer to the Quick Tip below. | |
2 | ||
3 | Click Design icon.
If you have made changes to the model after the design and want to use the old design results, you can refer to the Quick Tip below. | |
4 | ||
5 | Design code check calculations are in progress. |
|
6 | Click Report icon. | |
7 | Click Detailed Report button. | |
8 | Switch between the Summary Report tree view and review the results. | |
9 | Steel I Girder Code Check | |
10 | Click on the "Detailed Report" icon. It will open a detailed code check report for Steel I Girder. | |
11 | Field Splice Code Check | |
12 | Click on the "Detailed Report" icon. It will open a detailed code check report for Field Splice. | |
13 | Cross Frame Code Check |
|
14 | Click on the "Detailed Report" icon. It will open a detailed code check report for Cross Frame. | |
15 | Shear Stud Code Check In this summary, the total number of passed and failed shear stud code check regions is presented. | |
16 | Click on the "Detailed Report" icon. It will open a detailed code check report for Shear Stud. | |
17 | Pier Cap Code Check In the summary report, pier cap code checks are conducted using two design templates, namely for AASHTO (marked in red) and state specifications (marked in blue). The report presents the results of these code checks for the pier cap design. | |
18 | Click on the "Detailed Report" icon (marked in red). It will open a detailed code check report that includes pier cap code checks for flexure, shear, torsion, fatigue and reinforcement limits. | |
19 | Click on the "Detailed Report" icon (marked in blue). It will display state-specific checks in the detailed report. | |
20 | Pier Code Check In the summary report, the pier column code check presents the results of code checks as either D/C ratios or in Pass/Fail form, accordingly. | |
21 | Click on the "Detailed Report" icon . It will open a detailed code check report that includes pier column code checks for axial force-moment interaction, axial compression, shear, torsion, and reinforcement limits. | |
22 | Pier Footing Code Check The summary report for pier footing code check includes D/C values and Pass/Fail status for flexure, one-way shear, two-way shear, and reinforcement limits. | |
23 | Click on the "Detailed Report" icon . It will open a detailed code check report that includes pier footing code checks. | |
24 | Pile Capacity Check The summary report for pile capacity code check reports the maximum D/C value against the specified pile capacity. | |
25 | Click on the "Detailed Report" icon . It will open a detailed code check report that includes the most critical results, as well as all the results from different limit states. | |
26 | Load Rating Code Check In the summary report, you will find load rating reports for the employed girder, load rating station, limit state, and vehicles. These reports will include the corresponding rating factors, section properties, member capacities and analysis results. Additionally, a separate overall summary table will highlight the most critical code check stations, providing a concise overview of their rating results. | |
27 | Click on the "Detailed Report" icon . It will open a detailed code check report. |
To view the entire procedure explained on this page, please watch the recorded Video below.