Seismic Base Shear

Seismic Base Shear

Seismic base shear acting on the building is calculated by AEC|BOLT BIM Cloud library object depending on the parameters entered in Seismic Parameters Spreadsheet.

You should import the seismic base shear calculation object and seismic design category determination object from the AEC|BOLT BIM Cloud. There are 2 versions of both objects in the cloud. We will use the objects based on NYCBC 2014.

You must set the highlighted templates shown below in the Design Criteria spreadsheet.

  • Go to Seismic Parameters spreadsheet

  • Click Import Seismic Coefficients

  • Select New York Region

  • Click Import to import regional coefficients such as Ss, S1 and long term period from AEC|BOLT BIM Cloud.

  • Click Import Seismic Design Factors

  • Select B5 - Ordinary reinforced concrete shear walls to import response modification coefficient, overstrength factor, and deflection amplification from AEC|BOLT BIM Cloud.

These two features enable you to set the necessary seismic parameters quickly as demonstrated below.

 

The ground story level is a necessity for AEC|BOLT BIM Cloud object to determine the seismic design category automatically as illustrated above.

  • Select the ground story as 1st floor

  • Select the site class as D

The seismic design category will be determined as “B” which is given on the https://aecbolt.atlassian.net/wiki/spaces/BDS/pages/358645786 page.

  • Click Show to see the detailed report about seismic base shear acting on the building as demonstrated below

 

 

Related content

Seismic Parameters
Seismic Parameters
More like this
Seismic Base Shear Calculation
Seismic Base Shear Calculation
More like this
Seismic Base Shear Examples
Seismic Base Shear Examples
More like this
Main Wind Force Base Shear
Main Wind Force Base Shear
More like this
Flat Slab Concrete Building Example 1 [BDS-BD1]
Flat Slab Concrete Building Example 1 [BDS-BD1]
More like this
CSI Etabs Model
CSI Etabs Model
More like this