Surface loads to be applied to the deck can be specified by defining the parameters listed below.

Deck Load

Stage: Choose the stage at which to apply the load.

Deck: Specify the deck on which to apply the loads.

Fx: Force in the longitudinal direction along the PGL.

Fy: Force in the direction perpendicular to the PGL.

Fz (Gravity): A positive value indicates a load in the global -Z direction (or gravity direction). For typical loads, such as wearing surface loads (with the understanding that this load will be applied to the deck as a whole, while the wearing surface may only cover part of the deck, such as the area between the barriers and in this case, the Static Loads - Surface Load can be used ), the user should input positive values.

The Directions of Forces

See the figures provided below for further clarification on the directions of positive forces.

image-20241215-112416.png
Direction of Positive Fx
image-20241215-112601.png
Direction of Positive Fy
image-20241215-112737.png
Direction of Positive Fz (Gravity)