FAQ: Rigid Material and Section Definition

FAQ: Rigid Material and Section Definition

To establish a proper definition of a rigid material, users must exercise caution regarding two key parameters:

  • Ensuring that the unit weight of the rigid material is set to 0 is absolutely critical. Failure to do so could lead to the generation of excessive forces due to the self-weight of the rigid section.

  • To prevent the creation of an ill-conditioned matrix, users must exercise caution when assigning stiffness values, particularly when using high values such as >10000 times E*I or E*A. It is advisable to define stiffness values that are only 100 or 1000 times greater than those of the connected elements.

The below example serves, as an illustration, to grasp the logic behind defining rigid sections by comparing them with other sections within the project:

As seen below, the properties of "Rigid_Section1" are 100 times greater than those of "Column1," which happens to be the largest section in the project. Hence, it is duplicated, and its sectional properties are multiplied by 100. Moreover, "RigidMaterial1" has a specified modulus of elasticity of 29000ksi, approximately 6.54 times higher than the modulus of elasticity of ā€œFC_5_1/2ksiā€ concrete, which is 4428ksi. Consequently, the EI and EA values of the rigid section are 650 times larger than the largest section in the project. Additionally, the ā€œunit weightā€ and ā€œThermal Coeff.ā€ of "Rigid_Material1" are explicitly set to 0.

Duplicating a section might not be a good idea because it duplicates along with its shapes, and graphically, you will see a section in the FEA view at rigid section locations. Therefore, make sure that the section you use does not include any shapes.

Ā 

image-20240320-142753.png

Ā 

Related content

Sections [SIG]
Sections [SIG]
More like this
Insertion Point [EX1-SIG]
Insertion Point [EX1-SIG]
Read with this
Steps to Take: Steel Bridges- In the case of not successfully completing Finite Element Analysis
Steps to Take: Steel Bridges- In the case of not successfully completing Finite Element Analysis
More like this
Girder Layout [SIG]
Girder Layout [SIG]
Read with this
SPColumn Example 5:
SPColumn Example 5:
More like this
Materials [SIG]
Materials [SIG]
Read with this