Pier Cap Code Check T [EX1-PIG]
Please follow the instructions provided below to create Pier Cap/Bent code check template
1 | Navigate Templates for Code Check and Load Rating > Pier Cap Code Check |
|
2 | It is necessary to define 2 code check templates for pier cap and end bent control.
Enter the name in the Name column as follows:
| |
3 | Click three-dots icon on Load Combination Table and set SubstructureLCT. Since the Pier/Bent Cap is a substructure element the appropriate Load Combination Table to assign would be "SubstructureLCT". |
|
4 | Keep other parameters constant as follows. |
|
5 | “Procedures for Shear Resistance Parameters ß and θ ..”: Generalized | |
6 | “Include acxial effects on flexure and shear computation?” : Yes | |
7 | “Flexure Sign (Effective Shear Depth)”: Use Critical Shear Concurrent Bending Moment | |
8 | Click three-dots icon on Select State Provisions and assign FDOT both of them |
1 | Navigate to Pier Cap Code Check T under Templates for Code Check and Load Rating on the tree view. |
2 | Copy General from model inputs and paste into OpenBrIM. |
The Pier Cap Code Check have been created.
Pier Cap Code Check T |
---|
General |
PierCapCCT SubstructureLCT Generalized Yes Use Critical Shear Concurrent Bending Moment FDOT
EBCapCCT SubstructureLCT Generalized Yes Use Critical Shear Concurrent Bending Moment FDOT |