Combinations & Envelopes [FEA]

Combinations & Envelopes [FEA]

Items

This object serves multiple purposes, including filtering staged construction results by load type, extracting incremental/cumulative results from staged construction analysis, and combining transient loads such as wind loads, live loads to identify the most critical load effects.

Envelope[Yes/No]: If the "Envelope" option is set to "Yes," the component will find the critical case from the cases specified in the "Cases and Factors" column. However, if only one result case is defined in this column, selecting "Yes" or "No" for the envelope will not affect the results.

If the "Envelope" option is set to "No," the linear result combinations will operate by summing the results of multiple cases specified in the "Cases and Factors" column. Factors can be applied to the cases to achieve a weighted linear combination, but it is recommended to increase the loads according to the factors defined in AASHTO under limit states part. These factors should only be used if any increase needs to be made to compute the unfactored loads, such as including splice and other steel girder attachments by increasing the dead load by 5 percent. However, if only one result case is defined in this column, selecting "Yes" or "No" for the envelope will not affect the results.

Extreme Effects(Transient Loads)[Yes/No]: Selecting this option will exclude the selected result case from the combination if its value in the enveloped column is positive for minimums or negative for maximums. It is recommended to select "No" for permanent loads and "Yes" for transient loads. Choosing EE=Yes for permanent loads may lead to incorrect results since the result may be excluded from the maximum or minimum results.

Incremental[Yes/No]: If "no" is selected, the cumulative results from the selected stage will be extracted. If "yes" is selected, the incremental results from the selected stage will be extracted.

Load Type Filter[None/Dead Load/Imposed Dead ….]: If the "Filter By Load Type" option is set to "None," the component will extract the incremental or cumulative results from the selected stage without filtering it according to load types. However, if it is set to "Dead Load," the component will extract only the incremental or cumulative dead load results and exclude other load types such as imposed dead or wearing surface results from the selected stage. This option filters the results according to the load type. It is crucial to ensure that the load types are correctly assigned to the stages for accurate results extraction.

Case 1: The selected result case is the one that will be used in the computations. It is also possible to use other combinations as input for another case here.

Factor 1: Factor of the selected case.

Case 2:

Factor 2:

Case 3:

Factor 3:

Case 4:

Factor 4:

Case 5:

Factor 5:

More Items A

Case 6:

Factor 6:

Case 7:

Factor 7:

Case 8:

Factor 8:

Case 9:

Factor 9:

Case 10:

Factor 10:

More Items B

Case 11:

Factor 11:

Case 12:

Factor 12:

Case 13:

Factor 13:

Case 14:

Factor 14:

Case 15:

Factor 15:

More Items C

Case 16:

Factor 16:

Case 17:

Factor 17:

Case 18:

Factor 18:

Case 19:

Factor 19:

Case 20:

Factor 20:

Related content

Result Extraction Cases [EX1-STG]
Result Extraction Cases [EX1-STG]
More like this
Load Combination Table [SIG]
Load Combination Table [SIG]
More like this
Result Extraction Cases [EX1-PIG]
Result Extraction Cases [EX1-PIG]
More like this
Result Extraction [SIG]
Result Extraction [SIG]
More like this
Load Combination & Results Extraction & Documentation
Load Combination & Results Extraction & Documentation
More like this
FE Composites [FEA]
FE Composites [FEA]
More like this