Diaphragm Code Check (AASHTO) [SIG]

Diaphragm Code Check (AASHTO) [SIG]

The diaphragm code check takes into account axial force, bending, and shear. If the objective is to solely verify axial force, the cross frame code check object should be utilized.

Diaphragm: Diaphragm for code check

Code Check Template: The code check template is utilized to extract global parameters, results from finite element analysis, and limit states employed in the design process.

Station Offset of Section from Center: The code check station is measured from the center, where positive values indicate the right side when looking upstream along the PGL.

Panel Type [InteriorPanel/EndPanel]: The terms "end panel" and "interior panel" are used to describe the sections of a steel girder plate that are positioned at the ends and interior sections of the girder, respectively, as depicted in the accompanying figure. The interior panels comprise the remaining segments of the girder that lie between the end panels.

End Panel/Interior Panel

Stiffener

Has Long. Stiffener [NO/YES]: Select "Yes" if there is a longitudinal stiffener that passes through the diaphragm code check station.

Long. Stiff- Comp. Flange:

Has Trans. Stiffener [NO/YES]: Select "Yes" if the diaphragm code check station is located between two transverse stiffeners.

Transverse Stiffener Spacing: The spacing between the transverse stiffeners, as shown in the illustration below.

 

  

 

 

Related content

Cross Frame Code Check (AASHTO) [SIG]
Cross Frame Code Check (AASHTO) [SIG]
More like this
Lateral Bracing Code Check (AASHTO) [SIG]
Lateral Bracing Code Check (AASHTO) [SIG]
Read with this
Diaphragm Code Check (AASHTO) [STG]
Diaphragm Code Check (AASHTO) [STG]
More like this
Pier Cap [SIG]
Pier Cap [SIG]
Read with this
Steel I Girder Code Check (AASHTO) [SIG]
Steel I Girder Code Check (AASHTO) [SIG]
More like this
Shear Stud Code Check (AASHTO) [SIG]
Shear Stud Code Check (AASHTO) [SIG]
More like this