SPColumn Example 7:

SPColumn Example 7:

Verify the pure bending moment capacity of the section specified below:

Section dimensions:

bw=12 in

h= 28 in

Material properties:

f’c=4 ksi

εc= 0.003 in/in

β1= 0.85

Reinforcement parameters:

As= 12 in2

A's= 2 in2

fy=60 ksi

d (effective depth)= 26 in

εy= 0.002068 in/in

 

 

 

Library link: https://openbrim.org/objidc8h4mmhy7gnkdgz38j3k0s.libobj

Result Comparison

Output Parameters

Description

spColumn

BDS

Percent Difference

Output Parameters

Description

spColumn

BDS

Percent Difference

β1

 

0.85

0.85

0%

εt

 

0.0019

0.0019

0%

c (in)

N.A. depth

15.89

15.89

0%

φ

Capacity reduction factor

0.65

0.65

0%

φMn (kip-ft)

Moment capacity

721.66

721.66

0%