SPColumn Example 4:
SPColumn Example 4:
Verify the pure bending moment capacity of the section specified below:
Section dimensions:
bw=12 in
h= 28 in
Material properties:
f’c=4 ksi
εc= 0.003 in/in
β1= 0.85
Reinforcement parameters:
As= 9 in2
fy=60 ksi
d (effective depth)= 26 in
εy= 0.002068 in/in
Library link: https://openbrim.org/objid3xrmfd17e0uuhcl6een38d.libobj
Result Comparison
Output Parameters | Description | spColumn | BDS | Percent Difference |
---|---|---|---|---|
β1 |
| 0.85 | 0.85 | 0% |
εt |
| 0.00205 | 0.0020 | 1.98% |
c (in) | N.A. depth | 15.44 | 15.31 | 0.84% |
φ | Capacity reduction factor | 0.6508 | 0.65 | 0.12% |
φMn (kip-ft) | Moment capacity | 563.80 | 561.2957 | 0.44% |
, multiple selections available,