SPColumn Example 3:

SPColumn Example 3:

Verify the pure bending moment capacity of the section specified below:

Section dimensions:

bw=12 in

h= 28 in

Material properties:

f’c=10 ksi

εc= 0.003 in/in

β1= 0.85

Reinforcement parameters:

As= 7 in2

fy=60 ksi

d (effective depth)= 26 in

εy= 0.002068 in/in

 

 

 

Library link: https://openbrim.org/objidx06cmnslx3jjfcaxflgom.libobj

Result Comparison

Output Parameters

Description

spColumn

BDS

Percent Difference

Output Parameters

Description

spColumn

BDS

Percent Difference

β1

 

0.65

0.65

0%

εt

 

0.0093

0.0093

0%

c (in)

N.A. depth

6.33

6.33

0%

φ

Capacity reduction factor

0.90

0.90

0%

φMn (kip-ft)

Moment capacity

754.15

754.1471

4e-4%

 