Tributary analysis of the building is performed in this section.
Figure 1
To perform the tributary analysis with live load reduction;
→ Set previously imported Live Load Reduction Code For Columns template as illustrated in Figure 1
or
→ Go to Design Criteria and select “Live Load Reduction Code For Columns” template.
Go to Design Templates to see how to import a template.
Figure 2
→ Go to Tributary Correction Factors spreadsheet as shown in Figure 2
Figure 3
→ Edit the Tributary Area Factor (if needed) as illustrated in Figure 3.
Reducible live load areas of the columns are listed in the spreadsheet after the analysis is completed.
→ Click Run Tributary Analysis button as illustrated in Figure 1 to start analysis.
Add Comment