Proje linki : https://building.openbrim.org/objidzr6dkungmxh4u0iej9zvu2.project

Combination : 1.2DL+1.6LL

Analysis Source : CSI SAFE

Column No (Story)

D/C (Axial)

D/C (Shear)

D/C (Torsion)

Axial Force

Sway or Nonsway (X Direction)

Sway or Nonsway (Y Direction)

Slenderness (X Direction)

Slenderness (Y Direction)

Vs (X Direction)

Vs (Y Direction)

Is Torsion Critical ?

Tension

-

-

-

-

Not Required

Not Required

No

Tension

-

-

-

-

Required

Not Required

No

Tension

-

-

-

-

Required

Required

No

Tension

-

-

-

-

Required

Required

Yes

Tension

-

-

-

-

Not Required

Not Required

Yes

P10 (Bulkhead)

1.02

3.6681

0.002

Compression

Nonsway

Nonsway

Ignored

Ignored

Not Required

Not Required

No

C28 (2nd Floor)

0.3091

0.036

0.0042

Compression

Nonsway

Nonsway

Ignored

Ignored

Required

Not Required

No

C3 (3rd Floor)

0.4474

0.0465

0.0004

Compression

Nonsway

Nonsway

Ignored

Ignored

Required

Required

No

Compression

Nonsway

Nonsway

Ignored

Ignored

Required

Required

Yes

Compression

Nonsway

Nonsway

Ignored

Ignored

Not Required

Not Required

Yes

C60 (6th Floor)

0.36

0.3521

0.0004

Compression

Nonsway

Sway

Ignored

Ignored

Not Required

Not Required

No

P7 (Bulkhead)

0.86

1.9725

0.0762

Compression

Sway

Sway

Ignored

Ignored

Not Required

Not Required

No

P1 (8th Floor)

0.42

0.4001

0.0021

Compression

Nonsway

Nonsway

Not Ignored

Ignored

Not Required

Not Required

No

C1 (2nd Floor)

0.2758

0.1148

0.0005

Compression

Nonsway

Nonsway

Not Ignored

Not Ignored

Not Required

Not Required

No

C2 (8th Floor)

0.23

0.3214

0.0002

Compression

Nonsway

Nonsway

Ignored

Not Ignored

Not Required

Not Required

No

C73 (Roof)

0.65

1.016

0.0012

Compression

Sway

Nonsway

Not Ignored

Not Ignored

Not Required

Not Required

No

C47 (7th Floor)

0.34

0.3362

0.0011

Compression

Sway

Sway

Ignored

Not Ignored

Not Required

Not Required

No

C2 (2nd Floor)

0.26

0.1098

0.00001

Compression

Sway

Sway

Not Ignored

Not Ignored

Not Required

Not Required

No

Tablo 1 : Senaryolara ait D/C oranı kontrolü

Column No

Story

Parameter to Check

Value (Unit)

Affected Parameter

Value (Unit)

Combination (Analysis Source)

Description

C10

2nd Floor

Pu (Sustained Axial)

-306.7856 (kip)

δ

1.2915

1.2D+1.6L (SAFE)

Axial Force bölümünün Y yönü incelenmelidir. (Nonsway Column)

C11

3rd Floor

Pu (Sustained Lateral)

0.5914 (kip)

Mc

48.623 (kip-ft)

Axial Force bölümünün X yönü incelenmelidir. (Sway Column)

(ETABS sonuçları geldiğinde, Etabs sonuçlarına göre bu satır güncellenecektir.)

C12

3rd Floor

Pu (Sustained Lateral)

4.7063 (kip)

Mc

32.4366 (kip-ft)

Axial Force bölümünün Y yönü incelenmelidir. (Sway Column)

(ETABS sonuçları geldiğinde, Etabs sonuçlarına göre bu satır güncellenecektir.)

C13

6th Floor

ΣPu

-28136.6046 (kip)

Mc

29.7557 (kip-ft)

1.2D+1.6L (SAFE)

Axial Force bölümünün Y yönü incelenmelidir. (Sway Column)

C14

4th Floor

lu

108.004 (in)

δ

1.1544

1.2D+1.6L (SAFE)

Axial Force bölümünün X yönü incelenmelidir. (Nonsway Column)

C15

4th Floor

lu

108.004 (in)

Mc

119.9114 (kip-ft)

1.2D+1.6L (SAFE)

Axial Force bölümünün Y yönü incelenmelidir. (Sway Column)

Tablo 2 : BDS’den code check içine set edilen parametrelerin kontrolü

*** Kontrol edilen parametreler birden fazla parametreyi etkilemektedir. Tabloda gösterilen parametreler, kontrol edilen parametreden kaynaklı değişime uğrayabilecek önem arzeden parametredir. Eğer kontrol edilen parametre doğru olup etkilenen parametre hatalı ise ara parametreler kontrol edilmelidir. Ara parametrelerin tamamı ACI 318-14 şartnamesi tarafından hesaplanmaktadır.