Inputs
Pile Cap : Choose the pile cap to impose the nodal load on the top node of all piles.
Individual Piles : Select individual piles to apply the nodal load on their top node.
Stage : Select a stage to apply the load.
Fx : Force in X direction. The longitudinal direction along the alignment will correspond to the X direction.
Fy : Force in Y direction. The transverse direction along the alignment will correspond to the X direction.
Fz (Gravity) : A positive value indicates that the load is applied in the direction of gravity, while a negative value indicates that the load is applied in the opposite direction.
Mx : Moment in the longitudinal direction along the PGL.
My : Moment in the direction perpendicular to the PGL.
Mz : Moment in the vertical direction.
Add Comment