Bearing Result Extraction

Result Case: Specify the result extraction case from which the bearing reaction forces will be obtained.

Insertion Point: Specify the insertion point utilized for defining the bearings.

Envelope [NO/Fx/My]:

Min/Max [Abs. max/Max/Min]: Maximum represents positive values, minimum represents negative values, and absolute maximum refers to the largest value in magnitude, whether positive or negative.

Fx: Read-only value for the reaction force of the bearing along the X-axis.

Fy: Read-only value for the reaction force of the bearing along the Y-axis.

Fz: Read-only value for the reaction force of the bearing along the Z-axis.

Bearing Load

Stage:

Insertion Point:

Loads are applied according to Bearings Local Axis:

The loads defined using the Bearing Load object are applied based on the bearing's local axis, which aligns with the global (alignment) coordinate system if the parameter "Bearing Rotation" under Superstructure-FEA Bearings is defined as zero. Otherwise, the loads will be applied based on the rotated axis.