Follow the next steps to create a Load Combination Table for load rating.

1

Go to Combinations/Design Load Combinations/Load Rating Combination Table.

2

Under Dead Load column, select DC1, DC2 and DW accordingly, and specify load factors as 1.25 and 1.5, respectively.

3

Name the row as LoadRatingLCT.

Dead load definitions are completed.


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Load Rating Combination Table under Design Load Combinations on the tree view.

2

Copy Dead Load, Design Load, Legal Load, Emergency Load, and Permit Load from model inputs and paste into OpenBrIM.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Load Rating Combination Table

Dead Load

LoadRatingLCT	1.25	DC1	DC2	1.5	DW

Design Load

LoadRatingLCT	1.35	1.35	LL

Legal Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL

Emergency Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL

Permit Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL