Calculation of the live load reduction is explained in three examples which are LiveLoadReductionToType_Example, LiveLoadMaxReduction_Example and LiveLoadReductionDLTest_Example respectively.

Figure 1. LiveLoadReductionToType_Example

Dimensions : 20ft x 20ft in plan

In this example, live load reduction rates are calculated using 5 different live load class.

Live Load Classes

Live Load Type

Magnitude, psf

Live Load

50

Heavy Live Load

150

Group A LL

50

Passenger Vehicle Garage LL

50

Live Load Reducted

50

Reducible Area / Supported Floors

Columns/Reducible Area

Third Story, inch^2

Second Story, inch^2

First Story, inch^2

C1

14400

28800

43200

C2

14400

28800

43200

C3

14400

28800

43200

C4

14400

28800

43200

Supported Floors

1

2

3

Reduction Factor

Factor / Value

Third Story Column

Second Story Column

First Story Column

LFactorGeneral

1

0.96

0.88

LFactorHeavy

1

0.96

0.88

LFactorGroupA

1

1

1

LFactorPassengerVehicleGarages

1

0.96

0.88

C1 is loaded Group A class.

C2 is loaded Live Load class.

C3 is loaded Heavy Live Load class.

C4 is loaded Passenger Vehicle Garages class.

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1

-5

-10

-15

-5

-10

-15

C2

-5

-10

-15

-5

-10

-15

C3

-15

-30

-45

-15

-30

-45

C4

-5

-10

-15

-5

-10

-15

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1

-5

-10

-15

-5

-10

-15

C2

-5

-9.80

-14.20

-5

-9.80

-14.20

C3

-15

-29.40

-42.60

-15

-29.40

-42.60

C4

-5

-10

-15

-5

-9.80

-14.20

LiveLoadMaxReduction_Example

Dimensions : 28ft x 28ft in plan

In this example, live load reduction rates are calculated with maximum reduction values.

Live Load Class

Live Load Type

Magnitude, psf

Live Load

50

Reducible Area / Supported Floors

Columns/Reducible Area

Second Story, inch^2

First Story, inch^2

C1

176400

352800

C2

176400

352800

C3

176400

352800

C4

176400

352800

Supported Floors

1

2

Reduction Factor

Factor / Value

Second Story Column

First Story Column

LFactorGeneral

0.4

0.4

LFactorHeavy

1

0.8

LFactorGroupA

1

1

LFactorPassengerVehicleGarages

1

0.8

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-61.21

-122.43

-61.21

-122.43

C2

-61.26

-122.51

-61.26

-122.51

C3

-61.25

-122.50

-61.25

-122.50

C4

-61.28

-122.56

-61.28

-122.56

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-24.49

-48.97

-24.49

-48.97

C2

-24.50

-49.01

-24.50

-49.01

C3

-24.50

-49.00

-24.50

-49.00

C4

-24.51

-49.02

-24.51

-49.02

LiveLoadReductionDLTest_Example

Dimensions : 20ft x 20ft in plan

In this example, D/L ratio is calculated for maximum reduction.

Live Load Classes

Live Load Type

Magnitude, psf

Live Load

50

Heavy Live Load

150

Live Load

100

Heavy Live Load

200

Reducible Area / Supported Floors

Columns/Reducible Area

Third Story, inch^2

Second Story, inch^2

First Story, inch^2

C1

28800

79200

136800

Supported Floors

1

2

3

Reduction Factor

Factor / Value

Third Story Column

Second Story Column

First Story Column

LFactorGeneral

0.96

0.68

0.538

LFactorHeavy

1

0.8

0.8

LFactorGroupA

1

1

1

LFactorPassengerVehicleGarages

1

0.8

0.8

Live Load

Column

Load Class

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1 LL

-10

-22.5

-37.50

-10

-22.5

-37.50

C1 HLL

-15

-50

-85

-15

-50

-85

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1 LL

-9.60

-21.1

-32.5

-9.60

-17.30

-26.06

C1 HLL

-15

-45.8

-71

-15

-43

-73.8

Dimensions : 20ft x 20ft in plan

In this example, column’s tributary area not continuing bottom floors transfers other column’s tributary area.

Live Load Class

Live Load Type

Magnitude, psf

Live Load

75

Reducible Area / Supported Floors

Columns/Reducible Area

Second Story, inch^2

First Story, inch^2

C1

8640

23040

C2

8640

23040

C3

8640

23040

C4

8640

23040

C5

11520

11520

C6

11520

11520

Supported Floors

1

2

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-4.5

-15

-4.5

-15

C2

-4.5

-15

-4.5

-15

C3

-4.5

-15

-4.5

-15

C4

-4.5

-15

-4.5

-15

C5

-6

0

-6

0

C6

-6

0

-6

0

https://bim.aecbolt.com/platform/?application=inc&author=Verification_Examples_AEC%7CBOLT%2C+Inc&obj=objid7n45xnpgky3bdoogc2jvr