Follow the next steps to create steel I girder code check (AASHTO).
1 | Go to Superstructure Code Checks/Steel I Girder Code Check (AASHTO). | |
2 | Under General column, select Girder as G4 (exterior girder). | |
3 | Specify Station as 260 ft. (around 2nd span mid). | |
4 | Name the row G4Span. | |
5 | Enter Panel Type as InteriorPanel (Panel Type serves for web panel classification). | |
6 | Select Code Check Template as SuperstrCCT. | |
7 | Go to 2nd row (It’s for constructability checks for girder G1 at station 240 ft). | |
8 | Name the 2nd row G1SpanConst. | |
9 | Select Girder column G1. | |
10 | Enter Station as 240 ft. | |
11 | Enter Panel Type as InteriorPanel. | |
12 | Select Code Check Template as SuperstrConstCCT. | |
13 | Go to 3rd row (It’s for serviceability (Strength, Service and Fatigue) checks for girder G2 at station 160 ft (at pier)). | |
14 | Name the 3rd row G2Support. | |
15 | Select Girder column G2. | |
16 | Enter Station as 160 ft. | |
17 | Enter Panel Type as EndPanel. | |
18 | Select Code Check Template as SuperstrCCT. | |
19 | Switch to Reinforcement input column. | |
20 | Select Input Data Preference as Lumped in 1st row. | |
21 | For Deck Rebar Material column, click A615_60, if not defined click Import. | |
22 | From Database drop-down menu, select Steel Material Database. | |
23 | From Category drop-down menu, select Reinforcing Steel. | |
24 | From Asset drop-down menu, select A615_60 and click Import. | |
25 | Drag down the imported material to the 2nd and 3rd rows. | |
26 | Enter reinforcement area values specified in the corresponding cells. (Note that based on the input data preference, inputs not applicable automatically turns into N/A). | |
27 | Switch to Stiffener input tab. | |
28 | Select all Has Long. Stiffener column cells at once. Set its value to NO. | |
29 | Select all Has Trans. Stiffener column cells at once. Set its value to YES. | |
30 | Go to Stiffener Spacing Computation column. | |
31 | For the code checks at span region, keep the value Use Cross Frame Spacing as default. | |
32 | For the code check at support region, click three-dots icon, and select User Input. | |
33 | See Transverse Stiffener Spacing column turned from N/A to a numeric value. For this example, keep it value 82 in as default. | |
34 | Longitudinal stiffener = No for this example. (Long. Stiff-comp. flange:= distance btw longitudinal stiffener and compression flange (in).) |
Steel I girder code check (AASHTO) is completed.
Follow the below steps to copy and paste all inputs from our data set.
1 | Go to Steel I Girder Code Check (AASHTO) under Superstructure Code Checks on the tree view. |
2 | Copy General, Reinforcement, and Stiffener from model inputs and paste into OpenBrIM. |
Steel I Girder Code Check (AASHTO) | ||
---|---|---|
General G4Span G4 260 SuperstrCCT InteriorPanel ShoredConstruction G1SpanConst G1 240 SuperstrConstCCT InteriorPanel ShoredConstruction G2Support G2 160 SuperstrCCT EndPanel ShoredConstruction | Reinforcement G4Span Lumped A615_60 7.893 3 3.947 3 0 0 NULL NULL NULL NULL 0 0 1 G1SpanConst Lumped A615_60 7.893 3 3.947 3 0 0 NULL NULL NULL NULL 0 0 1 G2Support Lumped A615_60 7.893 3 3.947 3 0 0 NULL NULL NULL NULL 0 0 1 | Stiffener G4Span NO YES Use Cross Frame Spacing 82 5 G1SpanConst NO YES Use Cross Frame Spacing 82 5 G2Support NO YES User Input 82 5 |