Please follow the instructions provided below to create Pier Column code check.

1

In this section, please specify which column or columns the code check will be applied to.

2

Navigate to Substructure Code Checks > Pier Column Code Check

3

Click three-dots icon on Pier and select as Column1

(As a different way, the relevant column can be selected on the 3D view by clicking "Pick".)

4

Click three-dots icon on Template.

 

Select the PCCT1 "Pier Column Code Check" template defined in the previous steps for all.

5

Click three-dots icon on Section Data and click Edit.

Section Data (parameters) appear in the combobox.

6

Click three-dots icon on Section and click Select.

Select the "ColSec_P2" you want to code check for Pier Column (Column1).

7

Click three-dots icon on Stirrup Rebar Profile

Set Stirrup Rebar Profile as ASTMA615No6.

8

Navigate back to Inputs tab.

Set Tranverse Reinforcement Type as Tie.


Follow the below steps to copy and paste all inputs from our data set.

1

Navigate to Pier Column Code Check under Superstructure Code Checks on the tree view.

2

Copy Inputs and Section Data (spreadsheet) from model inputs and paste into OpenBrIM.

The Pier Column Code Check have been created.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Pier Column Code Check

Inputs

Section Data

PCC3	PCCT1	Column1	[[ColSec_P2, 0, ASTMA615No6, 6, 2, 2]]	0.003	0.75	0.005	0.9	Tie
ColSec_P2	0	ASTMA615No6	6	2	2