Follow the below instruction to Run Tributary Analysis

Table 1: Tributary Analysis

1

Go to Tributary under AEC|BOLT from tree view.

I want to make the tributary Area Factors of C21 and C25 columns 1.1 instead of "1".

I need the "Live Load Reduction" code for this, if this code is not imported, add it from Design Criteria.

2

Go to Tributary Correction Factors Tab at same spreadsheet.

Set the "Tributary Area Factors" of columns C21 and C25 to 1.1

You can see Reducible Area on this spreadsheet.

3

Come back to Tributary Analysis Settings and Run Tributary


Follow the below instruction to Run Slab Analysis

Table 2: Slab Analysis

1

Go to 1st floor under Slab Analysis from tree view.

Fill in the blanks in the spreadsheet according to your project.

Press the "Run Mesh" button to check the mesh quality.

2
 CAD view

3

Click “Run Slab Analysis” button.

After the analysis is complete, the Slab Analysis results is open

4
 Slab Analysis Combobox

5

6