Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#DEEBFF

Follow the next steps to create a Load Combination Table for load rating.

...

Go to Combinations/Design Load Combinations/Load Rating Combination Table.

...

Under Dead Load column, select DC1, DC2 and DW accordingly, and specify load factors as 1.0 and 1.0, respectively.

...

Name the row as LoadRatingLCT.

Tip

Dead load definitions are completed.

Info

Follow the next steps to add live load definitions.

...

Switch to Design Load column.

...

Click three-dots icon under LL column and select a live load case.

...

Legal Load, Emergency Load and Permit Load could be defined similarly with corresponding live load cases with desired vehicle definitions and load factors.

...

Go to Load Rating Combination Table under Design Load Combinations on the tree view.

...

Copy Dead Load, Design Load, Legal Load, Emergency Load, and Permit Load from model inputs and paste into OpenBrIM.

...

Load Rating Combination Table

...

Dead Load

Code Block
LoadRatingLCT	1.0000	1.0000	DC1	DC2	1.0000	1.0000	DW

...

Design Load

Code Block
LoadRatingLCT	1.3500	1.3500	LL

...

Legal Load

Code Block
LoadRatingLCT	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL

...

Emergency Load

Code Block
LoadRatingLCT	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL	1.3000	NULL

Permit Load

...

Info

After clicking on ‘Combinations> Design Load Combinations> Load Rating Combination Table' in the navigation treeview, follow the steps to define the Load Rating Combination Table. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titleLoad Rating Combination Table
Load Rating Combination Table [SIG]

1

🖱️ Click on Name cell and set name as LoadRatingLCT.

image-20250120-150539.pngImage Added

2

🖱️Enter the γDC (max) as 1.25 and γDC (min) as 1.

image-20250120-150600.pngImage Added

3

🖱️ Click three-dots icon on DC1 cell and select a Result Extraction Case as DC1.

image-20250120-150619.pngImage AddedImage Addedimage-20250120-150640.pngImage Added
4

🖱️ Click three-dots icon on DC2 cell and select a Result Extraction Case as DC2.

image-20250120-150656.pngImage Added

5

🖱️Enter the γDW (max) as 1.5 and γDW (min) as 1.

image-20250120-150713.pngImage Added

6

🖱️ Click three-dots icon on DW cell and select a Result Extraction Case as DW.

image-20250120-150736.pngImage Added

7

You can edit the Design Load from Design Load tab.

🖱️Enter the γLL (Inventory) as 1.75 and γLL (Operating) as 1.35.

🖱️ Click three-dots icon on LL cell and select a Result Extraction Case as LLHL93Case.

image-20250120-150806.pngImage Added

8

You can edit the Legal Load from Legal Load tab.

🖱️ Keep the Legal Load parameters as default.

Image Added
9

You can edit the Emergency Load from Emergency Load tab.

🖱️ Keep the Emergency Load parameters as default.

Image Added
10

You can edit the Permit Load from Permit Load tab.

🖱️ Keep the Permit Load parameters as default.

Image Added
11

Proceed to the next step to verify the model.

Anchor
Photo
Photo

Tip

The completed load rating combination table is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

...

Tip

To view the entire procedure explained on this page, please watch the recorded Video below.

...