Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Info

Please follow the instructions provided below to create Pier Cap/Bent code check template

1

Navigate Templates for Code Check and Load Rating > Pier Cap Code Check

2

It is necessary to define 2 code check templates for pier cap and end bent control.

Enter the name in the Name column as follows:

  • for Pier Cap: PierCapCT

  • for End Bent: EBCapCT

3

Click three-dots icon on Load Combination Table and set SubstructureLCT.

Since the Pier/Bent Cap is a substructure element the appropriate Load Combination Table to assign would be "SubstructureLCT".

4

Keep other parameters constant as follows.

5

“Procedures for Shear Resistance Parameters ß and θ ..”: Generalized

6

“Include acxial effects on flexure and shear computation?” : Yes

7

“Flexure Sign (Effective Shear Depth)”: Use Critical Shear Concurrent Bending Moment

8

Click three-dots icon on Select State Provisions and assign FDOT both of them

...