Select bar diameter and code check template for inregrity bottom bar. See Design Criteria to learn how to set code check templates as demonstrated in Figure 6.

Enter additonal rebar to add integrity rebars.

Click Verify All to run the code check for all the columns in the floor plan.

Clicl Verify Selected and select columnsto run the code check for the selected columns.

...

Figure 6

Status of each column will be set as passed or failed when the code check is completed. Click Show cell to see the detailed report.

After the code check is completed, required integrity bottom bar count will be displayed as read-only in the spreadsheet as illustrated in Figure 6. If entered additional rebar is not adequate, edit the rebar count and run the code check again.

...

Figure 7

Additional IBB rebar data will automatically be written in top reinforcements drawings as illustrated in Figure 7.