Axial force capacity parameters

Verification

Reference

OpenBrIM
v3Building Platform v3.200622

Reference Value

Diff. %

Pass/Fail (Axial Force)

OpenBrIM v3Building Platform v3.191030 200622 within rel. tol. of %0.1

true

1

0%

D/C (Axial)

OpenBrIM v3Building Platform v3.191030 200622 within rel. tol. of %2

0.6413

0.64

0.2%

Pnmax, Compressional strength

OpenBrIM v3Building Platform v3.191030 200622 within rel. tol. of %0.1

925611.3154

925611.3

2e-6%

Po, Nominal compressional strength

Building Platform v3.200622 within rel. tol. of %0.1

1157014.1442

1157014.1

4e-6%

Slenderness effect parameters

Verification

Reference

Building Platform v3.200622

Reference Value

Diff. %

Slenderness Effect (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1

1

0%

Pass/Fail (Critical buckling load) (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

true

1

0%

Pc, Critical buckling load (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1420868.0925

1420862.1

4e-4%

βdns, sustained load reduction ratio (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

0.5928

0.5928

3e-3%

Slenderness Effect (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1

1

0%

Pass/Fail (Critical buckling load) (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

true

1

0%

Pc, Critical buckling load, sway (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

4690887.5974

4690887.6

0%

βds, maximum sustained shear ratio (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

0

0

0%

Pc, Critical buckling load (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

6626294.2872

6626294.3

2e-7%

βdns, sustained load reduction ratio (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

0.5928

0.5928

3e-3%

Moment amplification parameters

Verification

Reference

Building Platform v3.200622

Reference Value

Diff. %

Mc, amplified design moment

Building Platform v3.200622 within rel. tol. of %0.1

52.4771

52.477

1e-4%

Mc, amplified moment (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

30.8655

30.8655

1e-4%

δ, moment magnification factor (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1

1

0%

Cm (Pδ), (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

0.6

0.6

0%

Minimum value of M2 (x-dir)

Building Platform v3.200622 within rel. tol. of %0.1

30.8655

30.8655

1e-4%

Mc, amplified moment (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

42.4401

42.4401

2e-5%

δ, moment magnification factor (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1

1

0%

Cm (PΔ,Pδ), (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

0.6

0.6

0%

δs, moment magnifier (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

1

1

0%

Minimum value of M2 (y-dir)

Building Platform v3.200622 within rel. tol. of %0.1

42.4401

42.4401

2e-5%