Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

1

🖱️ Click on Name cell and set name as LoadRatingLCT.

Image Removed

image-20250120-150539.pngImage Added

2

🖱️Enter the γDC (max) as 1.25 and γDC (min) as 1.

Image Removed

image-20250120-150600.pngImage Added

3

🖱️ Click three-dots icon on DC1 cell and select a Result Extraction Case as DC1.

Image Removedimage-20250120-150619.pngImage AddedImage Removedimage-20250120-150640.pngImage Added
4

🖱️ Click three-dots icon on DC2 cell and select a Result Extraction Case as DC2.

Image Removed

image-20250120-150656.pngImage Added

5

🖱️Enter the γDW (max) as 1.5 and γDW (min) as 1.

Image Removed

image-20250120-150713.pngImage Added

6

🖱️ Click three-dots icon on DW cell and select a Result Extraction Case as DW.

Image Removed

image-20250120-150736.pngImage Added

7

You can edit the Design Load from Design Load tab.

🖱️Enter the γLL (Inventory) as 1.75 and γLL (Operating) as 1.35.

🖱️ Click three-dots icon on LL cell and select a Result Extraction Case as LLHL93Case.

image-20241004-124931.pngImage Removedimage-20250120-150806.pngImage Added

8

You can edit the Legal Load from Legal Load tab.

🖱️ Keep the Legal Load parameters as default.

9

You can edit the Emergency Load from Emergency Load tab.

🖱️ Keep the Emergency Load parameters as default.

10

You can edit the Permit Load from Permit Load tab.

🖱️ Keep the Permit Load parameters as default.

11