Column LoadColumn: Specify the column to which the load will be applied. Stage: Choose the stage at which to apply the load. Distance from Top: Enter a value to define the location of the load with respect to the start of the column. Fx: Force in the longitudinal direction along the PGL. Fy: Force in the direction perpendicular to the PGL. Fz (Gravity): Force in the vertical direction. A positive value indicates a load in the global -Z or gravity direction. For usual loads (wearing surface loads - stay-in-place formwork loads), the user should input positive values. Mx: Moment in the longitudinal direction along the PGL. My: Moment in the direction perpendicular to the PGL. Mz: Moment in the vertical direction. |