Follow the next steps to create load rating reports.

...

Go to Load Rating/Steel I Girder Load Rating.

...

Under General column, name 1st column LoadRatReport.

...

Set G4 to Girder.

...

Enter Station input.

...

Set SIGLRT1 to LRTemplate.

...

Select Panel Type as Interior Panel.

...

Select Modular Ratio Comp. Method as EsbyEc.

...

Switch to Cover Plates.

...

Enter cover plate input data or keep the default values.

...

Switch to Section Losses.

...

Enter section loss input data or keep the default values.

Tip

Load rating report is completed.

...

Go to Steel I Girder Load Rating under Load Rating on the tree view.

...

Copy General, Cover Plates and Section Losses from model inputs and paste into OpenBrIM.

...

Steel I girder Load Rating

...

General

Code Block
LoadRatReport	G4	240.0000	SIGLRT1	Interior Panel	EsbyEc	N/A

Cover Plates

Code Block
LoadRatReport	0.0000	0.0000	0.0000	0.0000	0.0000	0.0000	0.0000	0.0000

Section Losses

...

Info

After clicking on ‘Load Rating> Steel I Girder Load Rating' in the navigation treeview, follow the steps to define the Steel I Girder Load Rating. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titleSteel I Girder Load Rating
Steel I Girder Load Rating [SIG]
1

(blue star) Click the three-dots icon on the Girder cell, and then set G4.

Image Added
2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the load rating template is defined in the next step.

Image Added

3

Insert excerpt
_Quick Tips
_Quick Tips
nameIssue
nopaneltrue

4

(blue star) Enter the Station as 240.

Image Added
5

(blue star) Click the three-dots icon on the Load Rating Template cell, and then set SIGLRT1.

Image Added
6

(blue star) Keep the Panel Type as default.

Image Added
7

(blue star) Click the three-dots icon on the Modular Ratio Comp. Method cell, and then set EsbyEc.

Image Added
8

(blue star) Keep the Modular Ratio as default.

Image Added
9

(blue star) Keep the Cover Plates and Section Losses parameters as default.

Image AddedImage Added
10

(blue star) Set name as LoadRatReport.

Image Added
11

Proceed to the next step to verify the model.

Anchor
Photo
Photo

Tip

The completed steel i girder load rating is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

...

Tip

To view the entire procedure explained on this page, please watch the recorded Video below.

...