Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Follow the next steps to create a Load Combination Table for load rating. |
1 | Go to Combinations/Design Load Combinations/Load Rating Combination Table. | |
2 | Under Dead Load column, select DC1, DC2 and DW accordingly, and specify load factors as 1.25 0 and 1.50, respectively. | |
3 | Name the row as LoadRatingLCT. |
...
1 | Switch to Design Load column. | |
2 | Click three-dots icon under LL column and select a live load case. | |
3 | Legal Load, Emergency Load and Permit Load could be defined similarly with corresponding live load cases with desired vehicle definitions and load factors. |
...
Load Rating Combination Table | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dead Load
| Design Load
| Legal Load
| Emergency Load
| Permit Load
|