Follow the next steps to create shear stud code check (AASHTO).

1

Go to Superstructure Code Checks/Shear Stud Code Check (AASHTO).

2

Under General column, select Girder and Set to G4.

3

Name the rows as CFKTypeCC and CFXType, respectively.

4

Select 1st and 2nd row together and click on three-dots icon under Code Check Template column.

5

Switch to Station Info.

6

Keep Check every nth station as 10 ft.

7

Click on three-dots icon of first cell under Mmax positive (LL+IM) stations and select Edit.

8

Set Mmax positive (LL+IM) stations.

...