After clicking on ‘Templates for Code Check and Load Rating> Pier Cap Code Check' in the navigation treeview, follow the steps to define the Pier Cap Code Check Template. You can use the collapsed documentation page below for more information on the explanations of each parameter.

 Pier Cap Code Check Template
1

🖱️ Click on Name cell and set name as PierCapTemp1.

image-20241005-092148.png

2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the load combination table is define in the next step.

3

 Quick Tip: Learn how to read issues

When encountering the warning as seen in OpenBrIM app, there is a "issue" , it is advised to review the parameters you have provided. This warning suggests that there might be a missing or incorrect parameter in your input. Check inputs to ensure they are accurate and complete.

When a warning is clicked, the reason can be displayed. The warning is expressed in the format of Component Group Name (can be viewed in the treeview) > User Defined Component Name (can be viewed in the spreadsheet name column) > Parameter Name (can be viewed in the spreadsheet column header).

After clicking on 'Superstructure > Connections > Bolted Field Splice' in the tree view, navigate to the Bolt category. Set the Bolt Property input. The issue will be resolved after these steps.

The screenshot demonstrates one example of two Bolted Field Splice components named BFS1 and BFS2 by the user, with parameter names Flange Bolt Property and Web Bolt Property.

4

🖱️ Click the three-dots icon on the Load Combination Table cell, and then set SubstructureLCT.

image-20241005-092229.png

5

🖱️ Keep Select State Provisions and PS Load Case as default.

image-20241005-092336.png

6

🖱️ Keep Design Parameters as default.

image-20241005-092448.png

7

🖱️ Go to Section Analysis Tab.

🖱️ Keep Ignore Rebar Tendon in Section Property Calc? as default.

🖱️ Set 1000 to Section Analysis Refinement (Total Fiber Count).

image-20241005-092751.png

8

To model all the pier cap code check template, copy the data below and paste the parameters into the first cell in OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

 Quick Tip: Learn how to Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Pier Cap Code Check Template

General

PierCapTemp1	SubstructureLCT	None	NULL
PierCapTemp2	SubstructureLCT	FDOT	NULL

The completed pier cap code check template is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

image-20241005-092954.pngimage-20241005-093034.pngimage-20241005-093141.png

To view the entire procedure explained on this page, please watch the recorded Video below.

20231030154159.mp4