Follow the next steps to create pier cap code check.

1

Go to Substructure Code Checks/Pier Cap Code Check.

2

Set PierCapCCT to Code Check Template.

3

Name the 1st row PierCapCC.

4

To set “Section”, click on three-dots icon and Select.

5

From drop-down menu, select pier cap section.

6

Input reinforcement data as:

Pier cap code check is completed.


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Pier Cap Code Check under Superstructure Code Checks on the tree view.

2

Copy General from model inputs and paste into OpenBrIM.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Pier Cap Code Check

General

PierCapCC	PierCapCCT	PierCap1	User Input	PierCapRec_Mid	ASTMA615No5	A615_60	6.0000	2.0000	10.0000	All
PCCC1	PierCapCCT2	PierCap1	User Input	PierCapRec_Mid	ASTMA615No5	A615_60	6.0000	2.0000	10.0000	All