Follow the next steps to define temperature loads.

1

Go to Loads/Temperature Load/Uniform Temperature Load.

2

There are two cases for expansion and contraction. For expansion,

Select Bridge, and Stage as TUExpStage.

3

Specify Temperature Change from Mean as 40F.

4

For contraction, go to the 2nd row. Select Bridge, and Stage as TUContrStage.

5

Specify Temperature Change from Mean as -40F.

6

Name these two cases as TU_Exp and TU_Contr, respectively.


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Uniform Temperature Load under Temperature Load on the tree view.

2

Copy related General from model inputs and paste into OpenBrIM.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Uniform Temperature Load

General

TU_Exp	BRG1	TUExpStage	40.0000
TU_Contr	BRG1	TUContrStage	-40.0000