Example Description

The frame object end releases are verified in this example.
Three models are used in the example. The models are identical, except for the end releases. Model A has a shear release, model B has an axial release and model C has a moment release.
This model results for the axial force and moment at the fixed support are compared with independent hand calculated results. Note that the models with releases are statically determinate and thus the independent results are obtained using basic statics.



Tested Features

  •  The end releases in a frame element, including

               Axial release

              Shear release

              Bending release

  •  The related frame static analysis



Library

Object Link: https://bim.aecbolt.com/objidm4uqmm3znpmyi5lf9rrdos.libobj

ModelOutput ParameterAEC|BOLT BIM Cloud AppSAP2000Independent

Percent Difference

(SAP2000 vs Independent)

Percent Difference

(AEC|BOLT BIM Cloud App vs Independent)

AFz (fixed support) k0000%0%
My (fixed support) k-ft6006006000%0%
BFz (fixed support) k0000%0%
My (fixed support) k-ft6006006000%0%
CFz (fixed support) k5550%0%
My (fixed support) k-ft0000%0%

Related content

Frame08 – Partial Fixity End Releases✔
Frame08 – Partial Fixity End Releases✔
More like this
Frame10 - End Offsets✔
Frame10 - End Offsets✔
More like this
Frame04 - Rotated Local Axes✔
Frame04 - Rotated Local Axes✔
More like this
Frame01 - General Loading✔
Frame01 - General Loading✔
More like this
Frame12 – No Tension and No Compression Frame Objects✔
Frame12 – No Tension and No Compression Frame Objects✔
More like this
Frame28 – Large Axial Displacements✔
Frame28 – Large Axial Displacements✔
More like this