Follow the next steps to create a pier cap code check.

1

Go to Templates for Code Check and Load Rating/ Pier Cap Code Check.

2

Under General, select Load Combination Table as SubstructureLCT.

3

Name the row as PierCapCCT.

4

Keep Procedures for Shear Resistance, Include axial effects, Flexure Sign and Select State Provisions parameters as default.

Pier cap code check template is completed.


1

Go to Pier Cap Code Check under Templates for Code Check and Load Rating on the tree view.

2

Copy General from model inputs and paste into OpenBrIM.


Pier Cap Code Check

General

PierCapCCT	SubstructureLCT	Generalized	Yes	Use Critical Shear Concurrent Bending Moment	None
PierCapCCT2	SubstructureLCT	Generalized	Yes	Use Critical Shear Concurrent Bending Moment	FDOT