Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

« Previous Version 11 Next »

After clicking on ‘Substructure Code Checks> Pier Cap Code Check' in the navigation treeview, follow the steps to define the Pier Cap Code Check. You can use the collapsed documentation page below for more information on the explanations of each parameter.

1

🖱️ Click the three-dots icon on the Pier Cap cell, and then set PierCap1.

image-20241005-103610.png
2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the code check template, pier cap section, transverse reinforcement profile, and shear reinforcement profile are defined in the next step.

image-20241005-103637.png
3

 Quick Tip: Learn how to read issues

When encountering the warning as seen in OpenBrIM app, there is a "issue" , it is advised to review the parameters you have provided. This warning suggests that there might be a missing or incorrect parameter in your input. Check inputs to ensure they are accurate and complete.

When a warning is clicked, the reason can be displayed. The warning is expressed in the format of Component Group Name (can be viewed in the treeview) > User Defined Component Name (can be viewed in the spreadsheet name column) > Parameter Name (can be viewed in the spreadsheet column header).

After clicking on 'Superstructure > Connections > Bolted Field Splice' in the tree view, navigate to the Bolt category. Set the Bolt Property input. The issue will be resolved after these steps.

The screenshot demonstrates one example of two Bolted Field Splice components named BFS1 and BFS2 by the user, with parameter names Flange Bolt Property and Web Bolt Property.

4

🖱️ Click the three-dots icon on the Code Check Template cell, and then set PierCapTemp1.

image-20241005-103732.png

5

🖱️ Change Code Check Loc (Dist. from Right End) to 10.

image-20241005-103911.png

6

🖱️ Keep Design Section w Rebars (or Tendons) as default.

image-20241005-104027.png

7

🖱️ Click three-dots icon on Override Section cell and select a Section as PierCapRec_Mid.

If you have reached this stage and you don't have a section to select, and if you want to use the Import Button, you can refer to the Quick Tip.

image-20241005-104123.pngimage-20241005-104201.png
8

🖱️ Keep Shear Reinforcement Data as default.

image-20241005-104423.png
9

🖱️Select Shear Reinforcement Profile as ASTMA615No5.

🖱️ Select Shear Reinforcement Material as A615_60.

image-20241005-104656.png
10

🖱️ Set 6 for Spacing of the Shear Reinforcement.

🖱️ Set 2 for No. of Legs of Shear Reinforcement.

image-20241005-104842.png
11

🖱️ Keep Check For as default.

image-20241005-105132.png
12

🖱️ Set name as PierCapCC1.

image-20241005-105224.png
13

To model all the pier cap code check, copy the data below and paste the parameters into the first cell in OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

 Quick Tip: Learn how to Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Pier Cap Code Check

General

PierCapCC1	PierCapTemp1	PierCap1	10.0000	Override Section	PierCapRec_Mid	User Input	ASTMA615No5	A615_60	6.0000	2.0000	All
PierCapCC2	PierCapTemp2	PierCap1	10.0000	Override Section	PierCapRec_Mid	User Input	ASTMA615No5	A615_60	6.0000	2.0000	All

The completed pier cap code checks are illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

image-20241005-105315.png

To view the entire procedure explained on this page, please watch the recorded Video below.