Follow the next steps to set boundary conditions for each bearing location (insertion point) that you have defined while creating the bridge layout.
1 | Go to Bearing Fixity on the tree view next to data spreadsheet. | |
2 | Set Tx/Ty/Tz/Rx/Ry/Rz. | |
3 | Set Transfer Force to Substructure as Yes for interior pier locations. | |
4 | Set Transfer Force to Substructure as No for start and end support locations. | |
5 |
Follow the below steps to copy and paste all inputs from our data set.
1 | Go to Bearing Fixity under Boundary Conditions on the tree view. | |
2 | Copy Articulation from model inputs and paste into OpenBrIM. |
Completed Bearing Fixity is illustrated below.
Bearing Fixity |
---|
Articulation BF1 IP1 Free Fixed Fixed Free Free Free 0 NO BF2 IP2 Free Fixed Fixed Free Free Free 0 NO BF3 IP3 Free Fixed Fixed Free Free Free 0 NO BF4 IP4 Free Fixed Fixed Free Free Free 0 NO BF5 IP5 Fixed Fixed Fixed Free Free Free 0 YES BF6 IP6 Fixed Fixed Fixed Free Free Free 0 YES BF7 IP7 Fixed Fixed Fixed Free Free Free 0 YES BF8 IP8 Fixed Fixed Fixed Free Free Free 0 YES BF9 IP9 Free Fixed Fixed Free Free Free 0 YES BF10 IP10 Free Fixed Fixed Free Free Free 0 YES BF11 IP11 Free Fixed Fixed Free Free Free 0 YES BF12 IP12 Free Fixed Fixed Free Free Free 0 YES BF13 IP13 Free Fixed Fixed Free Free Free 0 NO BF14 IP14 Free Fixed Fixed Free Free Free 0 NO BF15 IP15 Free Fixed Fixed Free Free Free 0 NO BF16 IP16 Free Fixed Fixed Free Free Free 0 NO |
0 Comments