Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

« Previous Version 5 Next »

Follow the next steps to create load rating reports.

1

Go to Load Rating/Steel I Girder Load Rating.

2

Under General column, name 1st column LoadRatReport.

3

Set G4 to Girder.

4

Enter Station input.

5

Set SIGLRT1 to LRTemplate.

6

Switch to Reinforcement column.

7

Enter rebar input data or keep the default values.

8

Switch to Cover Plates.

9

Enter cover plate input data or keep the default values.

10

Switch to Section Losses.

11

Enter section loss input data or keep the default values.

12

Switch to Stiffener.

13

Specify stiffener input data.

Load rating report is completed.


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Steel I Girder Load Rating under Load Rating on the tree view.

2

Copy General, Reinforcement, Cover Plates, Section Losses and Stiffener from model inputs and paste into OpenBrIM.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Steel I girder Load Rating

General

LoadRatReport	G4	240	SIGLRT1	InteriorPanel	ShoredConstruction

Reinforcement

LoadRatReport	A615_60	5	5	ASTMA615No5	ASTMA615No5	ASTMA615No4	ASTMA615No4	2	3	1

Cover Plates

LoadRatReport	0	0	0	0	0	0	0	0

Section Losses

LoadRatReport	0	0	0	0	0	0	0	0	0	0

Stiffener

LoadRatReport	NO	YES	Use Cross Frame Spacing	82	0
  • No labels

0 Comments

You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.