Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

Version 1 Next »


Follow the next steps to prepare the set of unfactored analysis results.

1

Under Combinations, go to Result Extraction Cases.

2

Go to 1st row, name it as DC1.

3

Go to the second column Filter by Load Type, click three-dots icon  and select Dead.

4

Go to the 3rd column Envelope, click three-dots icon and select NO.

5

Go to the 4th column Incremental, click three-dots icon and select NO.

6

Go to the 5th column Extreme Effects, click three-dots icon and select NO.

7

Go to Cases|Factors, click three-dots icon  to open edit window.

8

In the new spreadsheet, click Select under Case cell.

9

From the drop-down menu, select dead loads of the construction one-by-one.

 More about Result Extraction Cases

The first key parameter of this step is the Load Type specified in the Loading/Construction Stage.

Load Type serves as a filter when analysis results are extracted through construction stages (by Filter by Load Type parameter of Result Extraction Cases).

Filter by Load Type enables extracting analysis results based on load types, either cumulative or incremental.

To extract cumulative or incremental other two key parameters are:

i) Envelope:

ii)Incremental:

 

 

YES

Selecting YES (ex: )

NO

Selecting NO

Envelope

Extracts the most critical results of Cases|Factors when it contains more than one load case.

Finds the most critical results like deck pouring sequences, wind load, temperature load cases.

Extracts the results of Cases|Factors when it contains only one load case.

 

 

-

 

YES

Selecting YES (ex: )

NO

Selecting NO (ex: )

Incremental

Extracts incremental results of each stage added to Cases|Factors.

Obtains incremental results of a specific load type included in stages added to Cases|Factors.

Extracts cumulative results up to the last stage added to Cases|Factors.

Obtains cumulative results of a specific load type included in stages added to Cases|Factors(Ex: Assume the load type of barrier loading is specified as Superimposed - Assume the load type of girder erection and deck pouring sequences is Dead. Using Incremental = NO and Filter by Load Type = Superimposed gives the results of barrier loading).

 


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Result Extraction Cases under Combinations on the tree view.

2

Copy Items from model inputs and paste into OpenBrIM.

Completed input spreadsheet is illustrated below.


Follow the next steps to import load factors from pre-defined OpenBrIM Library definitions.

1

Go to Combinations/Design Load Combinations/Load Combination Table. This is the interface of load factors of limit states to be imported.


Follow the next steps to add load combinations for superstructure.

1

In Load Combination Table input spreadsheet, go to 1st row of Strength I column and click on three-dots icon.

2

Select Import.

3

Keep Source drop-down menu as default (OpenBrIM Platform ()).

4

Select Database from drop-down menu as AASHTO 9th Edition Load Combinations.

5

Select Category as Strength Limit States.

6

Select Asset as Strength I.

7

Scroll down in the Import OBPAASHTOLimitState menu and click Import.

8

In same way, repeat the same procedure to import the other corresponding limit states (Strength III, Strength IV, Strength V, Service II, Fatigue I and Fatigue II).

9

Name the Load Combination Table as SuperstructureLCT.

10

Imported limit states appears under Combinations/Design Load Combinations/Limit States.


Follow the next steps to add load combinations for substructure.

1

Go back to Combinations/Design Load Combinations/Load Combinations tab.

2

Create one more row and name it as SubstructureLCT. Import the limit states (StrengthI, StrengthIII, StrengthIV, StrengthV, ServiceI, ServiceII, ServiceIII, ServiceIV, FatigueI and FatigueII) in same way with the previous step.

3

Additonal limit states imported are appeared in Combinations/Design Load Combinations/Limit States spreadsheet.

4
 Quick Tip

Unfactored set of analysis results extracted from the construction stages.

Load factors from limit states.


Follow the next steps to specify the load cases (classes) combined with the load factors.

1

Go to Combinations/Design Load Combinations/Limit States one last time and select Load Cases 1.

2

Click on three-dots icon under DC1 column of StrengthI limit state and click Select.

3

Select DC1 (Remember, its content was composed of the corresponding construction stages in Combinations/Result Extraction Cases step).

4

In same way, keep selecting the load cases for the corresponding limit states.

5

Load cases not included in this example should remain as NULL.

Serviceability limit states (Strength, Service, and Fatigue) and load combinations are completed.


Follow the next steps to include a unique load combination for the constructability limit state.

1

Under Combinations/Design Load Combinations/Limit States, add a row named StrIConst.

2

Select DC1 and keep the rest of the load cases as NULL.

3

Enter γmax as 1.4.

4

Go to Combinations/Design Load Combinations/Load Combination Table one last time.

5

Add a row named SuperStrConstLCT.

6

Select StrengthI column as StrIConst, and keep the rest of the limit states as NULL.

Analysis loads & combinations of the code checks are completed.


Follow the next steps to create a Load Combination Table for load rating.

1

Go to Combinations/Design Load Combinations/Load Rating Combination Table.

2

Under Dead Load column, select DC1, DC2 and DW accordingly, and specify load factors as 1.25 and 1.5, respectively.

3

Name the row as LoadRatingLCT.

Dead load definitions are completed.


Follow the next steps to add live load definitions.

1

Switch to Design Load column.

2

Click three-dots icon  under LL column and select a live load case.

3

Legal Load, Emergency Load and Permit Load could be defined similarly with corresponding live load cases with desired vehicle definitions and load factors.


Follow the below steps to copy and paste all inputs from our data set.

1

Go to Limit States under Design Load Combinations on the tree view.

2

Copy Load Modifiers, Load Cases 1, Load Cases 2, and Load Cases 3 from model inputs and paste into OpenBrIM.

3

Go to Load Combination Table under Design Load Combinations on the tree view.

4

Copy Params from model inputs and paste into OpenBrIM.

5

Go to Load Rating Combination Table under Design Load Combinations on the tree view.

6

Copy Dead Load, Design Load, Legal Load, Emergency Load, and Permit Load from model inputs and paste into OpenBrIM.


 Quick Tip: Copy inputs to OpenBrIM

Copy the desired data with the automatic copy button in the upper left corner.

Click on the first cell in and use the Ctrl+V shortcut to paste.

If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

While pasting large data, it would be handy to turn of Auto-refresh .

Result Extraction Cases

Items

DC1	Dead	YES	NO	NO	[[SubstrConstStage, 1],[GirderStage, 1],[SIPFormworkStage, 1],[Cast1PourStage, 1],[Cast2PourStage, 1],[Cast3PourStage, 1],[Cast123GainStiffStage, 1],[Cast4PourStage, 1],[Cast5PourStage, 1],[Cast45GainStiffStage, 1]]
DC2	Imposed Dead	NO	NO	NO	[[FBarrierStage, 1]]
DW	Wearing Surface	NO	NO	NO	[[FutureWearingStage, 1]]
LL	Live (Vehicular + Impact)	YES	YES	NO	[[LLHL93Case, 1]]
LLFat	Live (Vehicular + Impact)	YES	YES	NO	[[LLFatCase, 1]]
WS	Wind on Structure	YES	YES	NO	[[WSCase, 1]]
TU	Temperature	YES	YES	NO	[[TUExpStage, 1],[TUContrStage, 1]]
BR	Braking	NO	NO	NO	[[LLBrakingCase, 1]]
CENT	Centrifugal	NO	NO	NO	[[LLCentCase, 1]]

Limit States

Load Modifiers

StrengthI	1	1	1
StrengthIII	1	1	1
StrengthV	1	1	1
ServiceI	1	1	1
ServiceII	1	1	1
FatigueI	1	1	1
FatigueII	1	1	1
StrengthII	1	1	1
StrengthIV	1	1	1
ServiceIII	1	1	1
ServiceIV	1	1	1
StrIConst	1	1	1

Load Cases 1

StrengthI	DC1	1.25	0.9	DC2	1.25	0.9	DW	1.5	0.65	LL	1.75	1.75	BR	1.75	1.75	WS	0	0	NULL	0	0	TU	1.2	0.5	CENT	1.75	1.75	NULL	1	1
StrengthIII	DC1	1.25	0.9	DC2	1.25	0.9	DW	1.5	0.65	LL	0	0	BR	0	0	WS	1	1	NULL	0	0	TU	1.2	0.5	CENT	0	0	NULL	1	1
StrengthV	DC1	1.25	0.9	DC2	1.25	0.9	DW	1.5	0.65	LL	1.35	1.35	BR	1.35	1.35	WS	1	1	NULL	1	1	TU	1.2	0.5	CENT	1.35	1.35	NULL	1	1
ServiceI	DC1	1	1	DC2	1	1	DW	1	1	LL	1	1	BR	1	1	WS	1	1	NULL	1	1	TU	1.2	0.5	CENT	1	1	NULL	1	1
ServiceII	DC1	1	1	DC2	1	1	DW	1	1	LL	1.3	1.3	BR	1.3	1.3	WS	0	0	NULL	0	0	TU	1.2	0.5	CENT	1.3	1.3	NULL	1	1
FatigueI	DC1	0	0	DC2	0	0	DW	0	0	LLFat	1.75	1.75	BR	1.75	1.75	WS	0	0	NULL	0	0	TU	0	0	CENT	1.75	1.75	NULL	1	1
FatigueII	DC1	0	0	DC2	0	0	DW	0	0	LLFat	0.8	0.8	BR	0.8	0.8	WS	0	0	NULL	0	0	TU	0	0	CENT	0.8	0.8	NULL	1	1
StrengthII	DC1	1.25	0.9	DC2	1.25	0.9	DW	1.5	0.65	LL	1.35	1.35	BR	1.35	1.35	WS	0	0	NULL	0	0	TU	1.2	0.5	CENT	1.35	1.35	NULL	1	1
StrengthIV	DC1	1.5	0.9	DC2	1.5	0.9	DW	1.5	0.65	LL	0	0	BR	0	0	WS	0	0	NULL	0	0	TU	1.2	0.5	CENT	0	0	NULL	1	1
ServiceIII	DC1	1	1	DC2	1	1	DW	1	1	LL	1	1	BR	1	1	WS	0	0	NULL	0	0	TU	1.2	0.5	CENT	1	1	NULL	1	1
ServiceIV	DC1	1	1	DC2	1	1	DW	1	1	LL	0	0	BR	0	0	WS	1	1	NULL	0	0	TU	1.2	0.5	CENT	0	0	NULL	1	1
StrIConst	DC1	1.4	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1

Load Cases 2

StrengthI	NULL	1	1	NULL	1	1	NULL	1.75	1.75	NULL	0	0	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1.75	1.75
StrengthIII	NULL	1	1	NULL	1	1	NULL	0	0	NULL	0	0	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0
StrengthV	NULL	1	1	NULL	1	1	NULL	1.35	1.35	NULL	0	0	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1.35	1.35
ServiceI	NULL	1.2	1	NULL	1	1	NULL	1	1	NULL	0.5	0.5	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1	1
ServiceII	NULL	1	1	NULL	1	1	NULL	1.3	1.3	NULL	0.5	0.5	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1.3	1.3
FatigueI	NULL	0	0	NULL	0	0	NULL	1.75	1.75	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1.75	1.75
FatigueII	NULL	0	0	NULL	0	0	NULL	0.8	0.8	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0.8	0.8
StrengthII	NULL	1	1	NULL	1	1	NULL	1.35	1.35	NULL	0	0	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1.35	1.35
StrengthIV	NULL	1	1	NULL	1	1	NULL	0	0	NULL	0	0	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0
ServiceIII	NULL	1	1	NULL	1	1	NULL	1	1	NULL	0.5	0.5	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	1	1
ServiceIV	NULL	1	1	NULL	1	1	NULL	0	0	NULL	1	1	NULL	1	1	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0
StrIConst	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1

Load Cases 3

StrengthI	NULL	1	1	NULL	1.5	0.75	NULL	1.5	0.9	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1.4	0.25	NULL	1	1	NULL	0	0
StrengthIII	NULL	1	1	NULL	1.5	0.75	NULL	1.5	0.9	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1.4	0.25	NULL	1	1	NULL	0	0
StrengthV	NULL	1	1	NULL	1.5	0.75	NULL	1.5	0.9	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1.4	0.25	NULL	1	1	NULL	0	0
ServiceI	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	0	0
ServiceII	NULL	0	0	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	0	0
FatigueI	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0
FatigueII	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0	NULL	0	0
StrengthII	NULL	1	1	NULL	1.5	0.75	NULL	1.5	0.9	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1.4	0.25	NULL	1	1	NULL	0	0
StrengthIV	NULL	1	1	NULL	1.5	0.75	NULL	1.5	0.9	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1.4	0.25	NULL	1	1	NULL	0	0
ServiceIII	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	0	0
ServiceIV	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	0	0
StrIConst	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1	NULL	1	1

Load Combination Table

Params

SuperstructureLCT	StrengthI	NULL	StrengthIII	StrengthIV	StrengthV	NULL	NULL	NULL	ServiceII	NULL	NULL	FatigueI	FatigueII
SubstructureLCT	StrengthI	NULL	StrengthIII	StrengthIV	StrengthV	NULL	NULL	ServiceI	ServiceII	ServiceIII	ServiceIV	FatigueI	FatigueII
SuperStrConstLCT	StrIConst	NULL	NULL	NULL	NULL	NULL	NULL	NULL	NULL	NULL	NULL	NULL	NULL

Load Rating Combination Table

Dead Load

LoadRatingLCT	1.25	DC1	DC2	1.5	DW

Design Load

LoadRatingLCT	1.35	1.35	LL

Legal Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL

Emergency Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL	1	NULL

Permit Load

LoadRatingLCT	1	LL	1	NULL	1	NULL	1	NULL	1	NULL