Analysis Setting

Table 1: AEC|BOLT

1

Go to Analysis. Under the AEC|BOLT tab, go to the Tributary section.
Click on Run Tributary Analysis. Analysis was done.

Verifies Tributary Analysis

2

If you have a Live Load Reduction Load, "LLR" should appear in the 1st column.

Verifies Live Load Reduction load template imported

3

Set "Do not Consider cut out if area is bigger 100 (ft²) rule" to "80". And make sure the value in the cell

Verifies "Do not Consider cut out if area is bigger 100 (ft²) rule" can be changed

4

Click the "Tributary Correction Factors" button under Tributary Analysis Setting.

Check see all the columns with live load reduction in this section.

Verifies "Tributary Correction Factors" operation.

5

In the C2 column in the 2nd row at spreadsheet, enter 1.10 to the "Tributary Area Factor" value.
Check the color change of the cell whose value has changed

Verifies "Tributary Correction Factors" operation.

6

Changes occurred in the "Changes After Last Code Check" cell because we made a change in Analysis Setting.

Click "View Changes" and check last change

Verifies that changes are saved

7

Click the "Run Tributary Analysis" button again. After the analysis is finished, check that the "Last Analysis Time" value has changed.

Verifies Last Analysis Time operation

8

Click the "Tributary Correction Factors" button again. And check that the changed value is present there.

Click the show button as in the figure and check the drawing created in CAD view.

Verifies Tributary Correction Factors CAD view

9
 CAD view

10

Go to Global FE Model. Change the "Run Mesh" button from False to True.

Click the Generate Fem button. Check values in table and 3D view

Verifies Generate FEM operations

11
 3D view

12

Click Run Analysis and perform Analysis.

Set "Line Forces" to the bottom 1st cell.
Set Fy (Shear) to 2nd cell and Self Weight.CASE to 3rd cell.
Compare the image on the screen with the image in the figure.

Verifies Analysis and 3D views of Analysis Results

13

Go to Mesh Setting (Slab) under Global FE Model. Set the value of Mesh Refinement to 500

Verifies Slab Mesh Settings

14

Go to Mesh Setting (Shearwall).

Set the value of Mesh Refinement in X&Y to 500 for SW1 and FW-1

Verifies Shearwall Mesh Settings

15

Go to FE Nodes in the tree view Check that FE Nodes table has been created

Verifies FE Nodes

16

Go to FE Lines in the tree view Check that FE Lines table has been created

Verifies FE Lines

17

Go to FE Surfaces in the tree view Check that FE Surfaces table has been created

Verifies FE Surfaces

18

19

20

21

  • No labels

0 Comments

You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.