Calculation of the live load reduction is explained in three examples which are LiveLoadReductionToType_Example, LiveLoadMaxReduction_Example and LiveLoadReductionDLTest_Example respectively.

Figure 1. LiveLoadReductionToType_Example

Dimensions : 20ft x 20ft in plan

In this example, live load reduction rates are calculated using 5 different live load class.

Live Load Classes

Live Load Type

Magnitude, psf

Live Load

50

Heavy Live Load

150

Group A LL

50

Passenger Vehicle Garage LL

50

Live Load Reducted

50

Reducible Area / Supported Floors

Columns/Reducible Area

Third Story, inch^2

Second Story, inch^2

First Story, inch^2

C1

14400

28800

43200

C2

14400

28800

43200

C3

14400

28800

43200

C4

14400

28800

43200

Supported Floors

1

2

3

Reduction Factor

Factor / Value

Third Story Column

Second Story Column

First Story Column

LFactorGeneral

1

0.96

0.88

LFactorHeavy

1

0.96

0.88

LFactorGroupA

1

1

1

LFactorPassengerVehicleGarages

1

0.96

0.88

C1 is loaded Group A class.

C2 is loaded Live Load class.

C3 is loaded Heavy Live Load class.

C4 is loaded Passenger Vehicle Garages class.

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1

-5

-10

-15

-5

-10

-15

C2

-5

-10

-15

-5

-10

-15

C3

-15

-30

-45

-15

-30

-45

C4

-5

-10

-15

-5

-10

-15

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1

-5

-10

-15

-5

-10

-15

C2

-5

-9.80

-14.20

-5

-9.80

-14.20

C3

-15

-29.40

-42.60

-15

-29.40

-42.60

C4

-5

-10

-15

-5

-9.80

-14.20

LiveLoadMaxReduction_Example

Dimensions : 28ft x 28ft in plan

In this example, live load reduction rates are calculated with maximum reduction values.

Live Load Class

Live Load Type

Magnitude, psf

Live Load

50

Reducible Area / Supported Floors

Columns/Reducible Area

Second Story, inch^2

First Story, inch^2

C1

176400

352800

C2

176400

352800

C3

176400

352800

C4

176400

352800

Supported Floors

1

2

Reduction Factor

Factor / Value

Second Story Column

First Story Column

LFactorGeneral

0.4

0.4

LFactorHeavy

1

0.8

LFactorGroupA

1

1

LFactorPassengerVehicleGarages

1

0.8

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-61.21

-122.43

-61.21

-122.43

C2

-61.26

-122.51

-61.26

-122.51

C3

-61.25

-122.50

-61.25

-122.50

C4

-61.28

-122.56

-61.28

-122.56

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-24.49

-48.97

-24.49

-48.97

C2

-24.50

-49.01

-24.50

-49.01

C3

-24.50

-49.00

-24.50

-49.00

C4

-24.51

-49.02

-24.51

-49.02

LiveLoadReductionDLTest_Example

Dimensions : 20ft x 20ft in plan

In this example, D/L ratio is calculated for maximum reduction.

Live Load Classes

Live Load Type

Magnitude, psf

Live Load

50

Heavy Live Load

150

Live Load

100

Heavy Live Load

200

Reducible Area / Supported Floors

Columns/Reducible Area

Third Story, inch^2

Second Story, inch^2

First Story, inch^2

C1

28800

79200

136800

Supported Floors

1

2

3

Reduction Factor

Factor / Value

Third Story Column

Second Story Column

First Story Column

LFactorGeneral

0.96

0.68

0.538

LFactorHeavy

1

0.8

0.8

LFactorGroupA

1

1

1

LFactorPassengerVehicleGarages

1

0.8

0.8

Live Load

Column

Load Class

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1 LL

-10

-22.5

-37.50

-10

-22.5

-37.50

C1 HLL

-15

-50

-85

-15

-50

-85

Reducted Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1 LL

-9.60

-21.1

-32.5

-9.60

-17.30

-26.06

C1 HLL

-15

-43

-71

-15

-45.8

-73.8

Go to the library object