General

Splice: Splice for code check

Code Check Template: The code check template is utilized to extract global parameters, results from finite element analysis, and limit states employed in the design process.

Res. Case To Find Points of Permanent Load: As per AASHTO 6.11.1.1, the effective span can be determined differently for cases involving simple spans and continuous spans. For continuous spans, the effective span length should be calculated based on the contraflexure under permanent loads or by considering simple supports and contraflexure. Following this approach, it is necessary to specify the result extraction case composed of permanent loads to determine the points of contraflexure and, consequently, the effective spans. This parameter can be used to specify the result extraction case that will be applied in calculations associated with contraflexure.