Follow the next steps to create a cross frame code check.

...

Go to Templates for Code Check and Load Rating/ Cross Frame Code Check.

...

Select Load Combination Table as SuperstructureLCT.

...

Name the row CFrameCCT.

Cross frame code check template is completed.
Tip
Info

After clicking on ‘Templates for Code Check and Load Rating> Cross Frame Code Check' in the navigation treeview, follow the steps to define the Cross Frame Code Check Template. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titleCross Frame Code Check Template
Cross Frame Code Check T [SIG]
1

🖱️ Click on Name cell and set name as CFrameCCT.

image-20250121-074618.pngImage Added

2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the load combination table is define in the next step.

Image Added
3

Insert excerpt
_

...

Quick Tips
_

...

Quick Tips
name

...

Cross Frame Code Check

Params

Code Block
CFrameCCT	SuperstructureLCT	NO

Bridge Parameters

Code BlockCFrameCCT 1000.0000 3.0000

Issue
nopaneltrue

1

Go to Cross Frame Code Check under Templates for Code Check and Load Rating on the tree view.

2

Copy General and Fatigue Parameters from model inputs and paste into OpenBrIM.

...

4

🖱️ Click the three-dots icon on the Load Combination Table cell, and then set SuperstructureLCT.

image-20250121-074638.pngImage Addedimage-20250121-074651.pngImage Added

5

🖱️Go to the Fatigue Parameters tab.

Set ADTT to 1250 and Number of Lanes Available to Trucks to 3.

Leave the rest of the parameters as default.

image-20250121-075019.pngImage Added

6

image-20250121-075110.pngImage Added Keep the parameters in the Tensile Resistance Parameters tab as default.

image-20250121-075207.pngImage Added

7

Proceed to the next step to verify the model.