Problem Description

This example is Problem 9 from the ASME 1972 Program Verification and Qualification Library (reference ASME 1972). A three-dimensional, fixed-base cooling tower is analyzed for an asymmetrical wind pressure loading. Radial displacements over the height of the tower are compared with published results.

...

https://openbrim.org/objidaye4i5eqevev5naq2omexq.project

Library Link: 

https://openbrim.org/objidv7rezcvhynimvwfng7b3qhobjidzk58m1hh5qnica2cnxzk4m.libobj


Elevation

Z (ft)

Output

Parameter

OpenBrIMSap2000Independent

Percent Difference

(SAP2000 vs Independent)

Percent Difference

(OpenBrIM vs Independent)

60Ux(jt 18) ft
-0.2501
-0.276-0.264%6.154%3.81%
45Ux(jt 17) ft
-0.2928
-0.325-0.313%4.839%5.55%
30Ux(jt 16) ft
-0.3357
-0.366-0.354%4.571%4.09%
15Ux(jt 15) ft
-0.3677
-0.397-0.392%1.795%5.72%
0Ux(jt 14) ft
-0.3899
-0.416-0.411%1.463%4.90%
-10Ux(jt 13) ft
-0.3982
-0.423-0.421%0.714%5.19%
-25Ux(jt 12) ft
-0.3997
-0.423-0.43-2%1.628%7.05%
-50Ux(jt 11) ft
-0.3802
-0.400-0.41-2%2.439%7.27%
-75Ux(jt 10) ft
-0.3391
-0.355-0.37-3%4.054%8.35%
-100Ux(jt 9) ft
-0.2849
-0.297-0.31-3%4.194%8.10%
-125Ux(jt 8) ft
-0.226
-0.235-0.25-3%6%9.60%
-150Ux(jt 7) ft
-0.1695
-0.176-0.18-1%2.222%5.83%
-175Ux(jt 6) ft
-0.1195
-0.124-0.13-1%4.615%8.08%
-200Ux(jt 5) ft
-0.0785
-0.081-0.080%1.25%1.88%
-225Ux(jt 4) ft
-0.0472
-0.048-0.050%-4%5.60%
-250Ux(jt 3) ft
-0.0267
-0.028-0.022%40%-33.50%
-260Ux(jt 2) ft
-0.0162
-0.016-0.011%60%-62.00%
-270Ux(jt 1) ft0.00000.0000.000%0

...