Excerpt | ||||
---|---|---|---|---|
| ||||
Inputs Line loads for pier caps can be applied based on the definitions made using the parameters below. Pier Cap LoadPier Cap: Choose the pier cap to impose the line load. Stage: Select a stage to apply the load. Start Normalized Distance From Right (relative0-1): The relative distance where the line load starts must be specified with a value between 0 and 1, where 0 corresponds to the initial node of the selected pier cap, and 1 corresponds to the final node. The initial node is defined along the alignment direction, looking upstation (to the right in the standard view). End Normalized Distance From Right (relative0-1): The relative distance where the line load ends must be specified with a value between 0 and 1, where 0 corresponds to the initial node of the selected pier cap, and 1 corresponds to the final node. The initial node is defined along the alignment direction, looking upstation (to the right in the standard view). Fx: Force in the X direction . The longitudinal direction along the alignment will correspond to the X directionwith respect to the global coordinate system. Fy: Force in the Y direction . The transverse direction along the alignment will correspond to the Y directionwith respect to the global coordinate system. Fz (Gravity): Force in the Z direction . A positive value will apply the load in the gravity direction, while a negative value will apply the load in the opposite directionwith respect to the global coordinate system. Mx: Moment in the longitudinal direction along the PGLglobal X-axis direction. My: Moment in the direction perpendicular to the PGLglobal Y-axis direction. Mz: Moment in the global Z vertical direction.
|
Content Comparison
General
Content
Integrations