Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Design of slab for punching shear stress is performed in this section.

...

Figure 1

Click “Verify Selected” Verify Selected button as shown in Figure 1 to verify the punching shear design for selected column or columns.

Click “Verify All” Verify All button as shown in Figure 1 to verify punching shear design of all columns of the corresponding story.

...

“Status” section in Figure 2 provides preliminary information about the adequency adequacy of the column strength against punching shear.

...

In the “Controlling Case” section illustrated in Figure 2, the most critical perimeter case (Interior, Edge, Corner) dominating punching shear design of the column is indicated. It is also possible to list and employ critical perimeter cases other than the most critical one in the punching shear design.

...