Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Decisions were made to match Aecbolt & Safe calculation results.

...

AECBOLT

  1. SW üzerine rigid area değil no weight slab yerleştirilecek

  2. Beam offset ile -Z ye taşınacak

  3. Shell Slab e z'de No weight slab will be placed on the SW, not a rigid area.

  4. It will be moved to -Z with beam offset

  5. In Shell Slab e z, there will be no offset ver t/z kadar, Column below L= L+ Slab Thickness, Slab unit Weight olmayacak

  6. Rigid zone yaratma işi creation job was settings oldu

  7. Beam intersecting slab areas mut must be 0 unit weight

...

SAFE

  1. Rigid Include Zone

The value of Column and Shearwall Properties from Aecbolt to Safe goes with the 'Include Rigid Zone' button checked. When analyzed in this way, there is a difference between Sum of Reaction and Hand Calculation. As we understand from this difference, for Column and Shearwall also take into account the weight of the 'Rigid Zone' defined.

...

(Rigid area is the area where the intersection of the Slab and the Column or Shearwall is.)

2. Calculation of Shearwall Height

While Column is exported to Safe, it is sent without subtracting the slab thickness from Story height. In sort if ‘Story height’ is 10 feet, Column height is also 10 feet.

...

This situation is not true and according to the new decision, Slab thickness will not be subtracted from Story height for Column below.
And Slab thickness will be subtracted from Story height for Column Above.

The reason for this decision is moment value calculation.

...

To Do : Cardinal Points

Cardinal points will be set to "top" instead of "middle" for columns and shearwalls.

...