Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Follow the next steps to create load rating reports. |
...
Go to Load Rating/Steel I Girder Load Rating.
...
...
Under General column, name 1st column LoadRatReport.
...
Set G4 to Girder.
...
Enter Station input.
...
...
Set SIGLRT1 to LRTemplate.
...
Switch to Reinforcement column.
...
...
Enter rebar input data or keep the default values.
...
Switch to Cover Plates.
...
...
Enter cover plate input data or keep the default values.
...
Switch to Section Losses.
...
...
Enter section loss input data or keep the default values.
...
Switch to Stiffener.
...
...
Specify stiffener input data.
Tip |
---|
Load rating report is completed. |
...
Go to Steel I Girder Load Rating under Load Rating on the tree view.
...
Copy General, Reinforcement, Cover Plates, Section Losses and Stiffener from model inputs and paste into OpenBrIM.
...
Steel I girder Load Rating
...
General
Code Block |
---|
LoadRatReport G4 240 SIGLRT1 InteriorPanel ShoredConstruction |
Reinforcement
Code Block |
---|
LoadRatReport A615_60 5 5 ASTMA615No5 ASTMA615No5 ASTMA615No4 ASTMA615No4 2 3 1 |
Cover Plates
Code Block |
---|
LoadRatReport 0 0 0 0 0 0 0 0 |
...
Section Losses
Code Block |
---|
LoadRatReport 0 0 0 0 0 0 0 0 0 0 |
Stiffener
...
Info |
---|
After clicking on ‘Load Rating> Steel I Girder Load Rating' in the navigation treeview, follow the steps to define the Steel I Girder Load Rating. You can use the collapsed documentation page below for more information on the explanations of each parameter. |
Expand | ||
---|---|---|
| ||
Steel I Girder Load Rating [SIG] |
1 | 🖱️ Click the three-dots icon on the Girder cell, and then set G1. | |||||||||||
2 | As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the load rating template is defined in the next step. | |||||||||||
3 |
| |||||||||||
4 | 🖱️ Enter the Station as 240. | |||||||||||
5 | 🖱️ Click the three-dots icon on the Load Rating Template cell, and then set SIGLRT1. | |||||||||||
6 | 🖱️ Keep the Panel Type as default. | |||||||||||
7 | 🖱️ Click the three-dots icon on the Modular Ratio Comp. Method cell, and then set EsbyEc. | |||||||||||
8 | 🖱️ Keep the Deck Reinforcement, Cover Plates and Section Losses parameters as default. | |||||||||||
9 | 🖱️ Set name as LoadRatReport. | |||||||||||
10 | Proceed to the next step to verify the model. |
Anchor | ||||
---|---|---|---|---|
|
Tip |
---|
The completed steel i girder load rating is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips. |
...
Tip |
---|
To view the entire procedure explained on this page, please watch the recorded Video below. |
...