Decisions were made to match Aecbolt & Safe calculation results.
...
AECBOLT
SW üzerine rigid area değil no weight slab yerleştirilecek
Beam offset ile -Z ye taşınacak
Shell Slab e z'de No weight slab will be placed on the SW, not a rigid area.
It will be moved to -Z with beam offset
In Shell Slab e z, there will be no offset ver t/z kadar, Column below L= L+ Slab Thickness, Slab unit Weight olmayacak
Rigid zone yaratma işi creation job was settings oldu
Beam intersecting slab areas mut must be 0 unit weight
...
SAFE
Rigid Include Zone
The value of Column and Shearwall Properties from Aecbolt to Safe goes with the 'Include Rigid Zone' button checked. When analyzed in this way, there is a difference between Sum of Reaction and Hand Calculation. As we understand from this difference, for Column and Shearwall also take into account the weight of the 'Rigid Zone' defined.
...
(Rigid area is the area where the intersection of the Slab and the Column or Shearwall is.)
2. Calculation of Shearwall Height
While Column is exported to Safe, it is sent without subtracting the slab thickness from Story Heightheight. In sort if ‘Story Height’ height’ is 10 feet, Column height is also 10 feet.
...
But while Shearwall is exported to Safe, Slab thickness is subtracted from Story Heightheight. In sort if ‘Story Height’ height’ is 10 feet and Slab thickness is 0.83 feet (10 inch), Shearwall height is also 9.17 feet.
In exports, both 'Column' and 'Shearwall' height will now be sent Story Height subtracted from 'Slab Thickness'.
...
This situation is not true and according to the new decision, Slab thickness will not be subtracted from Story height for Column below.
And Slab thickness will be subtracted from Story height for Column Above.
The reason for this decision is moment value calculation.
...
To Do : Cardinal Points
Cardinal points will be set to "top" instead of "middle" for columns and shearwalls.
...