Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Expand
titlePlate Girder
Plate Girder [SIG]
1

(blue star) Click three-dots icon on Girder Layout cell and set a layout.

Image Modified

 

2

Edit the plate girder dimensions. To enter a station-dependent dimension;

3

(blue star) Click three-dots icon on Top Flange Width cell and Edit (spreadsheet).

Image Modified

 

4

(blue star) Enter the Start Station as 0.

Image Modified
5

If the user enters the length along the girder, the end station and Station Difference will be calculated automatically. Conversely, if the user enters the end station, the length and Station Difference data will be calculated automatically.

6

(blue star) Set the Length parameter to 100. After this operation, the End Station and Station Difference parameters will be automatically calculated.

Image Modified
7

(blue star) Set the Station Difference parameter to 120. After this operation, the End Station and Length parameters will be automatically calculated.

Image Modified
8

(blue star) Set the Start Station parameter to 36. After this operation, the End Station, Station Difference and Length parameters will be automatically calculated.

Image Modified
9

(blue star) Please enter the following values sequentially:
1st row - Start Station: 0, End Station: 113.30, Top Flange Width: 16
2nd row - Start Station: 113.30, End Station: 136.20, Top Flange Width: 21
3rd row - Start Station: 136.20, End Station: 156.20, Top Flange Width: 21
4th row - Start Station: 156.20, End Station: 176.20, Top Flange Width: 21
5th row - Start Station: 176.20, End Station: 197.30, Top Flange Width: 21
6th row - Start Station: 197.30, End Station: 361.30, Top Flange Width: 18

Image Modified
10

Top Flange Thickness, Web Depth and Thickness, Bottom Flange Width and Thickness, Haunch Thickness, and Additional Haunch Width parameters can be defined similarly to Top Flange Width.

11

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the material is set in the next step.

12
Expand
titleQuick Tip

When encountering the warning as seen in OpenBrIM app, there is a "issue" , it is advised to review the parameters you have provided. This warning suggests that there might be a missing or incorrect parameter in your input. Check inputs to ensure they are accurate and complete.

Image RemovedWhen a warning is clicked, the reason can be displayed. The warning is expressed in the format of Warning Incoming Object Group > Object Name > Parameter Name.
Image Removed

After clicking on 'Superstructure > Connections > Bolted Field Splice' in the tree view, navigate to the Bolt category. Set the Bolt Property input. The issue will be resolved after these steps.

Image RemovedImage RemovedImage Removed

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
nameIssue
nopaneltrue

13

(blue star) Click three-dots icon on Top Flange Material cells and select a Material as A709 50.

Image RemovedImage RemovedImage Removed

14 ExpandtitleQuick Tip


The reason for selecting the material parameter instead of importing its value is that the material objects have already been imported previously.

If

there is no material to be set, follow the steps below:
- Click the three dots on the cell and select Import Material.
Image Removed- In the opened window, choose the material.
- Click the Import button.
Image Removed

you have reached this stage and you don't have a material to select, and if you want to use the Import Button, you can refer to the Quick Tip.

Image AddedImage AddedImage Added

14

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
nameImportMaterial
nopaneltrue

15

Web Material and Bottom Flange Material parameters can be defined similarly to Top Flange Material.

(blue star) Click three-dots icon on Web Material and Bottom Flange Material cells and select a Material as A709 50

Image Modified
16

You can edit the FE mesh settings of girders from FEA Settings tab.
(blue star) Keep the mesh size and number of result extraction as default.

Image Modified
17

When the steps are completed, the shared screenshot

should be

displayed in the adjacent cell

on the OpenBrIM screen

should be visible in the 3D view of OpenBrIM.

Image Modified
18

To model all the girders, copy the data below and paste the parameters into the first cell in OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
namePasteTip
nopaneltrue

...

Tip

To view the entire procedure explained on this page, please watch the recorded Video below.

...

20230921135036.mp4